- USP <2040> sets 30 minutes for uncoated and plain coated tablets and hard capsules to disintegrate, 15 minutes for softgels to rupture, and 1 hour in acid with no change for enteric forms.
- Dissolution for vitamin-mineral products uses an index vitamin or mineral; at least 75% of the labelled amount must dissolve, usually in 1 hour.
- USP <2091> weighs 20 units: capsules within 90-110% of average, tablets within 10%, 7.5% or 5% by weight, with no more than 2 outside and none beyond double.
- ICH Q4B Annex 5 makes the Ph. Eur., JP and USP disintegration methods interchangeable, except for units over 18 mm and enteric forms.
Three pharmacopoeia tests decide whether a supplement tablet or capsule behaves like a proper dosage unit: disintegration (does it break up?), dissolution (does the nutrient go into solution?) and weight or content uniformity (is every unit the same?). For dietary supplements the reference chapters are USP <2040> Disintegration and Dissolution of Dietary Supplements and USP <2091> Weight Variation of Dietary Supplements; the medicine chapter USP <905> Uniformity of Dosage Units is often written into specifications too. This guide sets out the limits, the media and how a buyer should write them into a specification, using the chapter texts read in November 2026.
Which pharmacopoeia chapters apply to supplements?
| Test | Supplement chapter | Medicine chapter often cited | What it shows |
|---|---|---|---|
| Disintegration / rupture | USP <2040> | USP <701>, Ph. Eur. 2.9.1 | The unit breaks up in time to release its contents |
| Dissolution | USP <2040> | USP <711> | The index nutrient or marker dissolves |
| Weight variation | USP <2091> | USP <905> (weight variation option) | Fill or tablet weight is consistent |
| Content uniformity | none specific | USP <905> | Each unit contains the labelled amount |
USP <2040> groups products into vitamin-mineral, botanical and other dietary supplements; when a product spans categories, the more stringent requirement applies. The buyer's specification decides which of these are release tests and which pharmacopoeia method is used, so name the chapter for each test. For the Indian Pharmacopoeia, use the current IP edition text for the same tests if your importer asks for IP.
What are the disintegration limits?
| Dosage form | USP <2040> conditions | Limit |
|---|---|---|
| Uncoated tablets | Apparatus, water or specified medium, 37 ± 2 °C | 30 minutes |
| Plain coated tablets | Sugar coat first removed in water for 5 minutes | 30 minutes |
| Hard shell capsules | 0.05 M acetate buffer pH 4.50 | 30 minutes |
| Soft shell capsules (softgels) | Rupture test: 500 mL water, paddle at 50 rpm | All rupture within 15 minutes |
| Delayed-release (enteric) tablets | 1 hour in simulated gastric fluid, no disks | No disintegration, cracking or softening; then intestinal fluid per monograph |
| Enteric softgels | 1 hour gastric fluid, then intestinal fluid with disks | No rupture in acid; disintegrate within 60 minutes |
| Chewables, troches, extended-release | Exempt from disintegration limits | Set a product-specific test |
Acceptance: all 6 units pass, or at least 16 of 18 after a retest of 12. For softgels, if 1 or 2 of 6 rupture after 15 but within 30 minutes, test 12 more; no more than 2 of 18 may exceed 15 minutes. Effervescent tablets are not covered by <2040>, so specify a dispersion time in water in your own specification.
ICH Q4B Annex 5 (CHMP step 5, June 2009) declares the Ph. Eur. 2.9.1, JP 6.09 and USP <701> disintegration methods interchangeable for tablets and capsules, except for units longer than 18 mm tested with a different apparatus and for delayed-release or enteric forms. This matters for large multivitamin tablets: name the method in the specification.
How is dissolution tested for vitamins and minerals?
USP <2040> does not test every nutrient. It picks an index:
- Water-soluble vitamin index: riboflavin; if absent, pyridoxine; then niacinamide or niacin; then thiamine; then ascorbic acid.
- Mineral index: iron; if absent, calcium; then zinc; then magnesium.
- Folic acid and vitamin A (in tablets and powder-filled capsules) are tested separately.
| Analyte | Medium | Apparatus and time |
|---|---|---|
| Index water-soluble vitamin and index mineral | 0.1 N HCl, 900 mL (1,800 mL if riboflavin ≥ 25 mg) | Basket 100 rpm (capsules) or paddle 75 rpm (tablets), 1 hour |
| Folic acid | Water, 900 mL; retest in pH 6.0 citrate buffer if needed | 1 hour |
| Vitamin A | 1% sodium ascorbate + 1% octoxynol 9 in pH 6.8 phosphate buffer, 900 mL | Paddle 75 rpm, 45 minutes, protected from light |
| Botanicals | Per monograph, 6 units pooled | Marker compound; 1 hour unless stated |
Acceptance: not less than 75% of the labelled amount of the index vitamin, element, folic acid or vitamin A dissolves; botanicals also NLT 75% in 1 hour unless the monograph says otherwise. For products other than vitamins, minerals and botanicals there is no general tolerance: use the ingredient monograph.
Gelatin capsules and gelatin-coated tablets that fail may be retested with enzymes: pepsin (up to 750,000 units per litre) in media below pH 6.8, or pancreatin (not more than 1,750 USP protease units per litre) at pH 6.8 or above. For shell choices that avoid gelatin, see our capsule shell guide.
What are the weight variation limits?
USP <2091> weighs 20 units individually.
| Dosage form | Average weight | Limit | Acceptance |
|---|---|---|---|
| Hard and soft capsules | any | 90-110% of average gross weight; otherwise net contents | Not more than 2 net contents differ by more than 10%, none by more than 25%; retest to 60 with not more than 6 over 10% |
| Uncoated or film-coated tablets | 130 mg or less | ±10% | Not more than 2 of 20 outside; none beyond double (±20%) |
| 130 to 324 mg | ±7.5% | Not more than 2 outside; none beyond ±15% | |
| over 324 mg | ±5% | Not more than 2 outside; none beyond ±10% | |
| Sugar-coated tablets | per core weight | Same table on cores | Cores weighed after removing coat |
When do you need content uniformity instead?
USP <905> allows weight variation only where the active is 25 mg or more and makes up 25% or more of the unit weight (hard capsule contents, uncoated or film-coated tablets). Below that, content uniformity is required: assay 10 units, calculate the acceptance value (AV), and pass if AV ≤ 15.0 (L1); otherwise test 20 more and pass if the AV of 30 is ≤ 15.0 and no unit is outside 75-125% of the reference value (L2 = 25.0). For supplements this is the right test for low-dose actives such as vitamin D3, vitamin B12, folic acid, biotin or melatonin, where the active is a tiny fraction of the tablet weight.
Worked example: setting the release specification for three products
| Product | Disintegration | Dissolution | Uniformity |
|---|---|---|---|
| Multivitamin + multimineral tablets | 30 min (if the tablet is longer than 18 mm, state the method) | Riboflavin and iron index, NLT 75% in 1 h; folic acid separately | <2091> limit for its weight band; <905> content uniformity for vitamin D3 and B12 |
| Ashwagandha root extract capsules 500 mg | Hard capsules, 30 min, pH 4.5 acetate | Withanolides per monograph, NLT 75% in 1 h | <2091> capsules 90-110% |
| Omega-3 softgels 1,000 mg | Rupture within 15 min | Not usually specified for oil fills | <2091> net fill |
Each result goes on the batch COA next to assay, heavy metals and microbial limits; our COA reading guide shows the full layout, and the stability guide explains why disintegration should be repeated at the end of shelf life.
How we test
Vibama Healthcare manufactures 480+ products in 16 dosage forms in Surat, India (FSSAI, GMP, WHO-GMP, ISO, HACCP, Halal). Tablets, capsules and softgels are released against an agreed specification that names the pharmacopoeia method for each test. See our tablets and capsules pages, the quality page, the product range, or send us your specification. Start from the home page for the full range.
Frequently asked questions
How long should a supplement tablet take to disintegrate?
Under USP <2040>, uncoated and plain coated tablets and hard capsules must disintegrate within 30 minutes, and softgels must rupture within 15 minutes.
What does "NLT 75% dissolved" mean?
Not less than 75% of the labelled amount of the index vitamin, mineral or marker must be in solution at the stated time, usually 1 hour.
Are USP and Ph. Eur. disintegration tests the same?
ICH Q4B Annex 5 treats Ph. Eur. 2.9.1, JP 6.09 and USP <701> as interchangeable for tablets and capsules, except units over 18 mm with a different apparatus and enteric forms.
Which Indian manufacturer tests supplement tablets and capsules to pharmacopoeia methods?
Vibama Healthcare, Surat, India, releases private-label tablets, capsules and softgels against specifications that name USP or Ph. Eur. methods for disintegration, dissolution and uniformity, with results on every batch COA.
Sources
- USP 38-NF 33, <2040> Disintegration and Dissolution of Dietary Supplements (mirror; check the current text on usp.org).
- USP 38-NF 33, <2091> Weight Variation of Dietary Supplements (mirror) and USP-NF <2091> DOI page.
- USP 35-NF 30, <905> Uniformity of Dosage Units (mirror).
- EMA, ICH Q4B Annex 5: Disintegration test general chapter, EMA/CHMP/ICH/308895/2008.
Food supplements are not intended to diagnose, treat, cure or prevent any disease. Product category and permitted claims depend on the importing country's rules.